AIRCRAFT LACING

Aircraft Lacing Materials: A Technical Guide for Aerospace Wire Harness Applications

The material a lacing cord is made from is not a secondary detail. In aerospace wire harness construction and maintenance, it is a primary engineering decision.

Aircraft wiring environments are demanding. A harness in a commercial avionics bay experiences different stresses to one routed near an engine mount. A wire bundle in a pressurised fuselage run lives in a different chemical environment to one in a wheel well or a military rotorcraft tail section.

A lacing material that performs correctly in one of those environments may degrade, lose tension, absorb fluid, or fail a fire resistance requirement in another. Getting that choice wrong — even if the installation technique is perfect — produces the same failure modes that correct lacing is designed to prevent.

This article explains the material types used in aerospace wire harness lacing, why aerospace environments demand specialised material properties, how different materials compare, and what inspection teams look for when materials age in service.

For informational purposes only. Material selection for specific aircraft must follow approved maintenance data, manufacturer documentation, and applicable workmanship standards.

Why Material Selection Matters

Aircraft lacing materials are the cords, tapes, and flat braided straps used to bundle, group, and route wire harnesses throughout an aircraft. They provide secondary bundle control — keeping grouped wires organised between primary support clamps, inside panels, and through conduit runs.

Lacing materials come in two main physical forms:

01
Round lacing cord
a twisted or braided strand used for spot ties, running lock stitches, and general harness tying. The round cross-section is practical for hand-tying knots and suits most general harness applications.
02
Flat lacing tape
a flat braided tape that distributes restraint force across a wider contact area. Used where insulation stress must be minimised — particularly for coaxial cables, fibre optic assemblies, and thin-wall wire insulations.
03
Bundle organisation
keeping wire groups together and in their intended routing paths.
04
Vibration control
preventing harness movement that drives insulation abrasion and conductor fatigue.
05
Chafing reduction
a correctly laced harness with appropriate materials does not create sharp contact points or allow wires to rub against structure.
06
Maintenance accessibility
lacing that is clean, intact, and correctly applied supports visual inspection and efficient rework.
07
EWIS integrity
harness bundling is part of the Electrical Wiring Interconnection System. Material compliance supports the system’s fire, separation, and reliability requirements.

Both forms are available in a range of materials. The material determines the cord’s performance across temperature, chemical exposure, fire, UV, humidity, and long-term aging.

The Role of Lacing Materials in Harness Management

ENVIRONMENTAL STRESSORS

Why Material Selection Matters

An aircraft wiring environment combines multiple simultaneous stressors. The bundling material must survive all of them — not just the most obvious one.

MATERIAL TYPES

Common Aircraft Lacing Material Types

Aerospace lacing materials are classified by fibre type. Each has a distinct performance profile that suits certain installation zones and rules out others.

1

Nylon Lacing Cord

General-purpose and widely available — one of the most common lacing cord materials in general aviation and commercial maintenance environments.

2

Polyester Lacing Cord

Offers better dimensional stability and moisture resistance than nylon, making it a more durable option for general aerospace harness applications.

3

PTFE / Fluoropolymer Lacing Cord

A high-performance material offering the broadest combination of chemical resistance, temperature stability, and non-flammability.

4

Waxed Lacing Cord

A finish, not a base material — typically nylon or polyester treated with a microcrystalline wax coating that significantly affects handling.

5

Fiberglass Lacing Cord and Tape

Specified where operating temperatures exceed the practical limits of nylon, polyester, and most fluoropolymer cords.

6

Nomex and Aramid-Based Lacing Materials

Used where fire resistance is the primary requirement, combined with a need for structural integrity under load.

COMPARISON OVERVIEW

Aircraft Lacing Material Types: At a Glance

PERFORMANCE FACTORS

Material Performance Factors for Aerospace Applications

Selecting a lacing material requires evaluating several performance factors simultaneously. No single property determines the right choice — it is the combination of properties against the installation zone requirements.

Tensile Strength

The cord must maintain its integrity under the mechanical loads applied during installation and service. Over-tightening during installation is a documented workmanship defect — but the cord must also hold its installed tension under vibration without creeping or relaxing. Correct tensile strength for the bundle diameter is specified in applicable workmanship standards.

Flexibility

Flexibility affects two things: how easily the cord can be worked into correct knots during installation, and how well it conforms to the bundle geometry during service. Stiffer materials are harder to tie and more likely to create localised pressure points at tie locations.

Abrasion Resistance

Lacing cord that contacts structure, adjacent harnesses, or is repeatedly handled during maintenance events must resist surface wear. A cord that frays generates fibre debris that can contaminate the wire bundle and create inspection ambiguity — it is difficult to determine whether fibre debris is from degraded lacing or from insulation damage.

Flame Resistance

EWIS regulatory frameworks require that materials used in wiring installations meet self-extinguishing requirements appropriate to the installation context. A lacing cord that propagates flame along a harness run defeats one of the primary safety objectives of correct wiring installation. Material data sheets should confirm flame behaviour — self-extinguishing, non-flammable, or inherently flame-resistant — before use in aircraft applications.

Thermal Stability

Thermal stability covers both high and low temperature performance. A cord that softens at high temperature loses its knot-holding ability. A cord that embrittles at low temperature (which can occur at altitude in unpressurised zones) is susceptible to fracture under vibration. Both failure modes produce a loose or broken lacing with the same result: bundle migration and chafing.

Fluid Resistance

The cord must not absorb, swell, or degrade chemically when exposed to the fluids present in its installation zone. For engine zones, this includes fuel, engine oil, and hydraulic fluid. For general airframe areas, it includes de-icing agents and cleaning solvents. For cargo or lower-fuselage zones, it may include moisture and contamination from freight.

Knot Security

The ability of a material to hold the correct knot under vibration over years of service is a core performance requirement. Smooth surfaces — like PTFE — require careful knot selection to ensure adequate friction at the contact points. Waxed surfaces increase friction and improve knot security for easier-to-work materials. Workmanship standards specify recommended knots for different bundle diameters and lacing types.

Vibration Survivability

A lacing material installed in a high-vibration zone must maintain its tension and knot integrity over thousands of hours of sustained vibrational load. Materials that creep, relax, or fatigue under vibration will progressively loosen, allowing the bundle to migrate. The failure mode is gradual and may not be visible at routine inspection intervals until chafing has already begun.

High-Temperature Aerospace Applications

Temperature is one of the most decisive material selection factors in aerospace harness lacing. Some zones require specific consideration.

Engine Bays and Firewall Zones

These are the most thermally demanding zones in the aircraft. Harness routing near turbine casings, exhaust ducts, and engine mounts can expose lacing materials to sustained high temperatures combined with significant vibration and fluid exposure. Polymer-based lacing is generally not suitable here. Fiberglass and ceramic-grade lacing materials are used for the most extreme zones; PTFE and Nomex are appropriate for zones with elevated but not extreme temperatures.

Avionics Bays

Avionics bays are not extreme-heat environments, but they can be thermally stable at elevated ambient temperatures due to heat generated by equipment. The primary material considerations here are flame resistance and chemical stability. Dense harness packing makes it important that materials do not degrade and produce debris that could contaminate connectors or equipment.

Unpressurised Zones and Wheel Wells

These areas experience the full thermal range of the aircraft’s operating envelope — from ground-level ambient temperatures up to high-altitude cold. UV exposure can be significant in zones with transparent or translucent panels. Materials in these zones must perform at temperature extremes and resist UV degradation across the aircraft’s service life.

High-Vibration Compartments

Helicopter rotor heads, tail sections, and engine-mount areas combine vibration with temperature and, often, fluid exposure. Material selection in these zones must address all three stressors simultaneously. A material that handles one well but fails another will still produce lacing failures in service.

 

EWIS and Material Considerations

The regulatory framework applicable to transport category aircraft treats EWIS — including the materials used to bundle and support wiring — as part of the aircraft’s safety system. This framing has direct implications for material selection.

F

Fire Protection Intent

EWIS rules require that materials used in wiring systems support fire protection objectives. A lacing cord that propagates flame, melts and drips, or generates hazardous smoke and toxic fumes when exposed to a heat source works against this intent. Self-extinguishing behaviour is the minimum expectation; non-flammable and inherently flame-resistant materials provide a higher level of assurance in critical zones.

I

Inspection and Maintenance Access

Lacing materials that degrade, fray, or discolour in service create inspection ambiguity. A cord in good condition provides a visual baseline. A degraded cord obscures the condition of the wiring underneath it and complicates the assessment of whether a harness needs rework. Materials with good long-term visual stability support reliable inspection outcomes.

R

Routing Stability Over Service Life

A material that maintains its tensile properties and knot security over decades of service keeps the harness in its designed routing path. A material that relaxes, creeps, or loses tension allows bundles to migrate — progressively creating the chafing and vibration failure modes that correct lacing is meant to prevent.

N

Non-Contamination Requirements

Aircraft maintenance guidance explicitly addresses the need to prevent contamination of wire bundles. A lacing material that sheds fibres, absorbs and retains moisture, or reacts chemically with wire insulation creates contamination risks that are difficult to identify and remediate after the fact. Approved aerospace-grade materials are selected partly to avoid these risks.

Material Aging and Inspection Issues

No lacing material lasts indefinitely without change. Maintenance and inspection teams need to know what degradation looks like for the materials they are working with.

What Inspectors Look For:

Inspection Frequency and Triggers

Lacing inspection is typically included in standard EWIS inspection programmes. Triggers for closer examination include: harness disturbance during unrelated maintenance, any work near engine or high-heat zones, evidence of fluid leaks near the harness run, and scheduled interval inspections defined by the aircraft’s ICA.

Aircraft Lacing Materials vs Plastic Cable Ties

The material comparison between lacing cord and plastic cable ties goes beyond just fibre type. The physical form and mechanical properties of each restraint method create different in-service behaviours.

Common Material Selection and Application Mistakes

Using the Wrong Material for the Zone

Installing nylon cord in an engine-adjacent area or near a fuel zone is a material specification error regardless of how well the cord is installed. The material will degrade in conditions it was not designed for. The result — loose lacing, contamination, and eventually bundle migration — is indistinguishable from poor workmanship.

Assuming All Waxed Cord Is Equivalent

Waxed cord varies in base material, wax type, and performance specification. A waxed nylon cord and a waxed polyester cord with a fluoropolymer-compatible finish are not interchangeable. The base material determines the temperature ceiling, fluid resistance, and UV performance. Always verify the full material specification, not just the surface finish.

Over-Tightening

Over-tightening is listed as a workmanship defect in aerospace standards. A cord applied too tightly can deform the bundle, damage insulation, and create precisely the insulation failure it is installed to prevent. The correct installation tension allows the bundle to be grouped without deformation — a rough guide used in some maintenance environments is that a correctly tensioned tie should allow two fingers to slide under the cord.

Ignoring Fluid Compatibility

A lacing cord that absorbs or reacts with the fluids in its installation zone will fail progressively and silently. Hydraulic fluid wicking into a nylon cord under a junction box, or engine oil penetrating a waxed cord in a firewall zone, will not be visible until the cord has already lost its integrity. Check fluid compatibility before specifying materials for any zone with potential fluid exposure.

Using Unapproved Materials

Commercial string, electrical tape, and general-purpose ties are not aerospace lacing materials. Using unapproved materials introduces unverified flame, chemical, and structural risks into the EWIS. Some non-aerospace materials contain dyes or compounds that react with wire insulation over time. Material selection must follow approved data and applicable specifications.

Incorrect Knot for the Material

Material and knot are paired. A smooth fluoropolymer cord requires knot types that create sufficient friction at the contact points to prevent slippage. Using the same knot as for a waxed nylon cord on a PTFE cord without adjusting the technique produces a tie that loosens under vibration. Workmanship standards specify recommended knots by bundle diameter and material type — these are not interchangeable defaults.

Best Practices for Selecting Aircraft Lacing Materials

Future Trends in Aerospace Lacing Materials

Material development in aerospace is driven by the same pressures that drive broader aircraft design: lower weight, longer service life, broader environmental performance, and compliance with increasingly detailed EWIS requirements.

Conclusion

Aircraft lacing material selection is a technical decision with direct safety implications. The wrong material in the wrong environment produces the same failure modes — bundle migration, chafing, insulation damage, and arcing risk — that correct lacing is designed to prevent.

Nylon, polyester, PTFE, waxed cord, fiberglass, and Nomex each have their place in aerospace harness construction. Each also has environments where they are unsuitable. A material that performs well in a pressurised interior run may be completely inadequate in an engine zone. A material that handles beautifully in ambient conditions may embrittle at altitude or in a wheel well.

The foundation of correct material selection is the same as the foundation of correct lacing practice: follow the approved data, understand the installation zone, and treat every component of the EWIS — including the cord that holds it together — as part of the system’s safety performance.

FREQUENTLY ASKED

Frequently Asked Questions

What materials are aircraft lacing cords made from?

Aerospace lacing cord and tape are manufactured in nylon, polyester, PTFE and other fluoropolymers, waxed variants of the above, fiberglass, and Nomex/aramid materials. Each material type has different performance characteristics for temperature, chemical resistance, flame behaviour, and flexibility. Material selection depends on the installation zone and the stressors present.

What is the difference between lacing cord and lacing tape?

Lacing cord is a round twisted or braided strand used for spot ties and general harness tying. Lacing tape is a flat braided strip that distributes restraint force across a wider surface area. Tape is preferred for sensitive cables — coaxial, fibre optic, and thin-wall insulation types — where concentrated pressure from a round cord could cause insulation stress or cold flow.

 
Why does lacing material matter for EWIS compliance?

Under EWIS regulatory frameworks, the materials used to bundle and support wiring are treated as components of the aircraft’s safety system. Lacing materials must meet fire resistance requirements, be compatible with the installation environment, not degrade in ways that contaminate or damage wiring, and maintain their function across the aircraft’s service life. Using unapproved or inappropriate materials introduces risks that extend beyond the lacing itself.

 
How do I know which lacing material to use for a specific aircraft zone?

Material selection should follow the approved data for your specific aircraft — typically the manufacturer’s Standard Wiring Practices Manual (SWPM) or the applicable workmanship standard. Where manufacturer instructions are unavailable, general maintenance advisory guidance provides acceptable methods. The key factors to assess are zone temperature range, fluid exposure, vibration level, UV exposure, and fire protection requirements.

 
How long does aerospace lacing cord last in service?

Service life depends on the material, the installation zone, and the maintenance history. Aerospace-grade lacing cord installed in appropriate conditions can remain in service for decades. Materials used outside their rated parameters degrade faster. Common degradation indicators include fraying, embrittlement, discolouration, knot loosening, and wax deterioration. These should be assessed at every harness access event.

Â